Table 3. AC Characteristics
(VDD33 = 3.3 V ±5%, TA = –20 to 85 °C)
Parameter
Symbol
Test Condition
Min
Typ Max Unit
Input Clock Frequency (CLKIN)
FEC[2:0] = 000 (non FEC)
INFRQSEL[2:0] = 001
INFRQSEL[2:0] = 010
INFRQSEL[2:0] = 011
INFRQSEL[2:0] = 100
INFRQSEL[2:0] = 101
INFRQSEL[2:0] = 110
fCLKIN
No FEC Scaling,
FXDDELAY = 1
19.436 — 21.685
38.872 — 43.369 MHz
77.744 — 86.738
155.48 — 173.48
310.97 — 346.95
621.95 — 693.90
Input Clock Frequency (CLKIN)
FEC[2:0] = 001 (forward FEC)
INFRQSEL[2:0] = 001
INFRQSEL[2:0] = 010
INFRQSEL[2:0] = 011
INFRQSEL[2:0] = 100
INFRQSEL[2:0] = 101
INFRQSEL[2:0] = 110
fCLKIN
255/238 FEC Scaling,
FXDDELAY = 1
18.142
36.284
72.568
145.13
290.27
580.54
— 20.239
— 40.478 MHz
— 80.955
— 161.91
— 323.82
— 647.64
Input Clock Frequency (CLKIN)
FEC[2:0] = 010 (reverse FEC)
INFRQSEL[2:0] = 001
INFRQSEL[2:0] = 010
INFRQSEL[2:0] = 011
INFRQSEL[2:0] = 100
INFRQSEL[2:0] = 101
INFRQSEL[2:0] = 110
fCLKIN
238/255 FEC Scaling,
FXDDELAY = 1
20.826
41.652
83.305
166.61
333.22
666.44
— 23.234
— 46.465 MHz
— 92.934
— 185.87
— 371.74
— 743.47
Input Clock Frequency (CLKIN)
FEC[2:0] = 100 (forward FEC)
INFRQSEL[2:0] = 001
INFRQSEL[2:0] = 010
INFRQSEL[2:0] = 011
INFRQSEL[2:0] = 100
INFRQSEL[2:0] = 101
INFRQSEL[2:0] = 110
fCLKIN
255/237 FEC Scaling
Minimum input frequency is
in the 155 MHz range,
FXDDELAY = 1
N/A
N/A
N/A
144.52
289.05
578.11
N/A
N/A
N/A
N/A MHz
N/A
N/A
— 161.23
— 322.46
— 644.92
Input Clock Frequency (CLKIN)
FEC[2:0] = 101 (reverse FEC)
INFRQSEL[2:0] = 001
INFRQSEL[2:0] = 010
INFRQSEL[2:0] = 011
INFRQSEL[2:0] = 100
INFRQSEL[2:0] = 101
INFRQSEL[2:0] = 110
fCLKIN
237/255 FEC Scaling
Minimum input frequency is
in the 155 MHz range,
FXDDELAY = 1
N/A
N/A
N/A
167.31
334.62
669.25
N/A
N/A
N/A
N/A MHz
N/A
N/A
— 186.66
— 373.31
— 746.61
Note: The Si5321 provides a 1/32x, 1/16x, 1/8x, 1/4x, 1/2x, 1x, 2x, 4x, 8x, 16x, 32x, 64x, or 128x clock multiplication function
with an option for additional frequency scaling by a factor of 255/238, 238/255, 255/237, 237/255, 66/64, or 64/66 for
FEC rate conversion.
Rev. 2.5
7