Parameter
Symbol
Test Condition
Min
No image rejection calibration. Re-
30
jection at the image frequency. RF =
460 MHz
With image rejection calibration. Re-
40
jection at the image frequency. RF =
460 MHz
No image rejection calibration. Re-
30
jection at the image frequency. RF =
Image Rejection (IF = 468.75
kHz)
ImREJ
915 MHz
With image rejection calibration. Re-
40
jection at the image frequency. RF =
915 MHz
No image rejection calibration. Re-
35
jection at the image frequency. RF =
169 MHz
With image rejection calibration. Re-
45
jection at the image frequency. RF =
169 MHz
EZR32WG330 Data Sheet
Electrical Specifications
Typ
Max
Unit
40
—
dB
55
—
dB
45
—
dB
52
—
dB
45
—
dB
60
—
dB