English
Language : 

EZR32WG330 Datasheet, PDF (56/87 Pages) Silicon Laboratories – Building and home automation
EZR32WG330 Data Sheet
Electrical Specifications
Table 4.23. I2C Fast-mode Plus (Fm+)
Parameter
Symbol
Min
Typ
Max
Unit
SCL clock frequency
fSCL
0
─
10001
kHz
SCL clock low time
tLOW
0.5
─
─
µs
SCL clock high time
tHIGH
0.26
─
─
µs
SDA set-up time
tSU,DAT
50
─
─
ns
SDA hold time
tHD,DAT
8
─
─
ns
Repeated START condition set-up time
tSU,STA
0.26
─
─
µs
(Repeated) START condition hold time
tHD,STA
0.26
─
─
µs
STOP condition set-up time
tSU,STO
0.26
─
─
µs
Bus free time between a STOP and a START
tBUF
0.5
─
─
µs
condition
Note:
1. For the minimum HFPERCLK frequency required in Fast-mode Plus, see the I2C chapter in the EZR32WG Reference Manual.
4.17 Radio
All minimum and maximum values are guaranteed across the recommended operating conditions of supply voltage and from –40 to
+85 °C unless otherwise stated. All typical values apply at VDD = 3.3 V and 25 °C unless otherwise stated. The data was collected while
running off the internal RC oscillator (HFRCO).
silabs.com | Smart. Connected. Energy-friendly.
Rev. 1.1 | 55