Table 6. IEC 60747-5-2 Insulation Characteristics*
Parameter
Symbol Test Condition
Characteristic
WB
NB SOIC-16 14 LD LGA Unit
SOIC-16 14 LD LGA w/ Pad
Maximum Working Insulation
Voltage
VIORM
891
560
Method a
After Environmen-
tal Tests
Subgroup 1
1590
896
(VIORM x 1.6 = VPR,
tm = 60 sec, Partial
Discharge < 5 pC)
373
V peak
597
Input to Output Test Voltage
Method b1
(VIORM x 1.875 = V
VPR
PR, 100%
Production Test,
tm = 1 sec,
Partial Discharge <
5 pC)
1375
1050
700
V peak
After Input and/or
Safety Test
Subgroup 2/3
(VIORM x 1.2 = VPR,
1018
672
448
tm = 60 sec, Partial
Discharge < 5 pC)
Highest Allowable Overvolt-
age (Transient Overvoltage,
VTR
tTR = 10 sec)
Pollution Degree (DIN VDE
0110, Table 1)
6000
2
4000
2
2650 V peak
2
Insulation Resistance at TS,
VIO = 500 V
RS
>109
>109
>109

*Note: The Si823x is suitable for basic electrical isolation within the safety limit data. Maintenance of the safety data is
ensured by protective circuits. The Si823x provides a climate classification of 40/125/21.