Si823x
Table 2. Absolute Maximum Ratings1
Parameter
Storage Temperature2
Ambient Temperature under Bias
Input-side Supply Voltage
Symbol
TSTG
TA
VDDI
Min
Typ
–65
—
–40
—
–0.6
—
Max
+150
+125
6.0
Units
°C
°C
V
Driver-side Supply Voltage
VDDA, VDDB –0.6
—
30
V
Voltage on any pin with respect to ground
VIN
–0.5
— VDD + 0.5
V
Output Drive Current per channel
Lead Solder Temperature (10 sec.)
IO
—
—
10
mA
—
—
260
°C
Maximum Isolation (Input to Output) (1 sec)
WB SOIC-16
—
—
6500
VRMS
Maximum Isolation (Output to Output) (1 sec)
WB SOIC-16
—
—
2500
VRMS
Maximum Isolation (Input to Output) (1 sec)
NB SOIC-16
—
—
4250
VRMS
Maximum Isolation (Output to Output) (1 sec)
NB SOIC-16
—
—
2500
VRMS
Maximum Isolation (Input to Output) (1 sec)
14 LD LGA without thermal pad
—
—
3850
VRMS
Maximum Isolation (Output to Output) (1 sec)
14 LD LGA without thermal pad
—
—
650
VRMS
Maximum Isolation (Input to Output) (1 sec)
14 LD LGA with thermal pad
—
—
1850
VRMS
Maximum Isolation (Output to Output) (1 sec)
14 LD LGA with thermal pad
—
—
0
VRMS
Notes:
1. Permanent device damage may occur if the absolute maximum ratings are exceeded. Functional operation should be
restricted to the conditions as specified in the operational sections of this data sheet. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
2. VDE certifies storage temperature from –40 to 150 °C.
Table 3. Regulatory Information*
CSA
The Si823x is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
VDE
The Si823x is certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
UL
The Si823x is certified under UL1577 component recognition program. For more details, see File E257455.
*Note: Regulatory Certifications apply to 1.5 kVRMS rated devices which are production tested to 1.8 kVRMS for 1 sec.
Regulatory Certifications apply to 2.5 kVRMS rated devices which are production tested to 3.0 kVRMS for 1 sec.
Regulatory Certifications apply to 3.75 kVRMS rated devices which are production tested to 4.5 kVRMS for 1 sec.
Regulatory Certifications apply to 5.0 kVRMS rated devices which are production tested to 6.0 kVRMS for 1 sec.
For more information, see "9.Ordering Guide" on page 37.
10