English
Language : 

S-93C46C Datasheet, PDF (7/39 Pages) Seiko Instruments Inc – 3-WIRE SERIAL E2PROM
Rev.1.1_00
3-WIRE SERIAL E2PROM
S-93C46C/56C/66C/76C/86C
 Absolute Maximum Ratings
Table 1
Item
Symbol
Absolute Maximum Rating
Unit
Power supply voltage
Input voltage
Output voltage
Operation ambient temperature
Storage temperature
VCC
VIN
VOUT
Topr
Tstg
−0.3 to +6.5
V
−0.3 to +6.5
V
−0.3 to VCC + 0.3
V
−40 to +85
°C
−65 to +150
°C
Caution The absolute maximum ratings are rated values exceeding which the product could suffer physical
damage. These values must therefore not be exceeded under any conditions.
 Recommended Operating Conditions
Table 2
Item
Symbol
Condition
Power supply voltage VCC
High level input voltage VIH
Low level input voltage VIL
READ, EWDS
WRITE, ERASE,EWEN
WRAL, ERAL
VCC = 4.5 V to 5.5 V
VCC = 2.7 V to 4.5 V
VCC = 1.6 V to 2.7 V
VCC = 4.5 V to 5.5 V
VCC = 2.7 V to 4.5 V
VCC = 1.6 V to 2.7 V
Ta = −40°C to +85°C
Min.
Max.
Unit
1.6
5.5
V
1.8
5.5
V
2.5
5.5
V
2.0
0.8 × VCC
0.8 × VCC
0.0
VCC
V
VCC
V
VCC
V
0.8
V
0.0
0.2 × VCC
V
0.0
0.15 × VCC
V
 Pin Capacitance
Item
Input capacitance
Output capacitance
Symbol
CIN
COUT
VIN = 0 V
VOUT = 0 V
Table 3
Condition
(Ta = +25°C, f = 1.0 MHz, VCC = 5.0 V)
Min.
Max.
Unit
−
8
pF
−
10
pF
 Endurance
Table 4
Item
Symbol Operation Ambient Temperature
Min.
Endurance
NW
Ta = −40°C to +85°C
106
*1. For each address (Word: 16-bit)
Max.
−
Unit
cycle / word*1
 Data Retention
Item
Data retention
Table 5
Symbol
Operation Ambient Temperature
Min.
Max.
Unit
−
Ta = +25°C
Ta = −40°C to +85°C
100
−
year
50
−
year
7