English
Language : 

S-93C46C Datasheet, PDF (17/39 Pages) Seiko Instruments Inc – 3-WIRE SERIAL E2PROM
Rev.1.1_00
3-WIRE SERIAL E2PROM
S-93C46C/56C/66C/76C/86C
3. 3 Erasing data (ERASE)
To erase 16-bit data at a specified address, set all 16 bits of the data to "1", change the CS pin to "H", and then
input the ERASE instruction and address following the start bit. There is no need to input data. The data erase
operation starts when the CS pin goes to "L". When the clocks more than the specified number have been input,
the clock pulse monitoring circuit cancels the ERASE instruction. For details of the clock pulse monitoring circuit,
refer to " Function to Protect Against Write due to Erroneous Instruction Recognition".
CS
tCDS
Verify
Standby
SK
1 2 34 5 67 8 9
DI
<1> 1 1 A5 A4 A3 A2 A1
A0
High-Z
DO
tSV
busy
ready
tHZ1
tPR
High-Z
Figure 8 Data Erase Timing (S-93C46C)
CS
tCDS
Verify
Standby
SK
1 2 3 4 5 6 7 8 9 10 11
DI
<1> 1 1
A6 A5 A4 A3 A2 A1 A0
DO
High-Z
x: S-93C56C
A7: S-93C66C
tSV
busy
ready
tHZ1
tPR
High-Z
Figure 9 Data Erase Timing (S-93C56C/66C)
CS
tCDS
Verify
Standby
SK
1 2 3 4 5 6 7 8 9 10 11 12 13
DI
<1> 1 1
A8 A7 A6 A5 A4 A3 A2 A1 A0
DO
High-Z
x: S-93C76C
A9: S-93C86C
tSV
busy
ready
tHZ1
tPR
High-Z
Figure 10 Data Erase Timing (S-93C76C/86C)
17