English
Language : 

S-808XXC Datasheet, PDF (27/58 Pages) Seiko Instruments Inc – SUPER-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
Rev.4.3_00
SUPER-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
S-808xxC Series
2. S-80844KLUA-D2AT2G, S-80844KLY-x-G
Table 19
(Ta = 25 °C unless otherwise specified)
Item
Detection voltage*1
Release voltage
Current consumption
Operating voltage
Output current
Response time
Detection voltage
temperature
coefficient*3
Symbol
Condition
Min.
−VDET
+VDET
ISS
VDD
IOUT
tPLH


VDD = 6.0 V

Output transistor, VDD = 1.2 V
Nch, VDS = 0.5 V VDD = 2.4 V
Output transistor,
Pch, VDS = 0.5 V
VDD = 4.8 V

4.295


0.95
0.23
1.60
0.36

∆ − VDET
Ta = −40 to 85 °C

∆Ta • −VDET
Typ.
4.450*2

1.0

0.50
3.70
0.62

±100
Max.
4.605
4.700
3.0
10.0



60
Unit
Test
circuit
V
1
V
1
µA
2
V
1
mA
3
mA
3
mA
4
µs
1
±350 ppm/°C 1
*1. −VDET: Actual detection voltage value
*2. Specified detection voltage value (−VDET(S))
*3. The temperature change ratio in the detection voltage [mV/°C] is calculated by using the following equation.
[ ] [ ] [ ] ( ) ∆ − VDET mV/°C *1 = −VDET(S) Typ. V *2 × ∆ − VDET ppm/°C *3 ÷ 1000
∆Ta
∆Ta • −VDET
*1. Temperature change ratio of the detection voltage
*2. Specified detection voltage
*3. Detection voltage temperature coefficient
Seiko Instruments Inc.
27