English
Language : 

S1009 Datasheet, PDF (18/43 Pages) Seiko Instruments Inc – SUPER-LOW CURRENT CONSUMPTION SUPER HIGH-ACCURACY VOLTAGE
SUPER-LOW CURRENT CONSUMPTION SUPER HIGH-ACCURACY VOLTAGE DETECTOR WITH DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING)
S-1009 Series
Rev.5.1_00
„ Precautions
• Do not apply an electrostatic discharge to this IC that exceeds the performance ratings of the built-in electrostatic
protection circuit.
• In CMOS output product of the S-1009 Series, the feed-through current flows at the detection and the release. If the
input impedance is high, oscillation may occur due to the voltage drop by the feed-through current during releasing.
• In CMOS output product oscillation may occur when a pull-down resistor is used, and falling speed of the power
supply voltage (VDD) is slow near the detection voltage.
• When designing for mass production using an application circuit described herein, the product deviation and
temperature characteristics of the external parts should be taken into consideration. SII shall not bear any
responsibility for patent infringements related to products using the circuits described herein.
• SII claims no responsibility for any disputes arising out of or in connection with any infringement by products
including this IC of patents owned by a third party.
18
Seiko Instruments Inc.