English
Language : 

GS6152 Datasheet, PDF (69/80 Pages) Semtech Corporation – Multi-Rate 6G UHD-SDI
Table 5-1: Register Descriptions - Standard Address Space (Continued)
Address Register Name Parameter Name
Bit
Slice
R/W
Reset
Value
Description
Enable for manual timed measurement
PRBS_MON_MANUAL_
START
using the Re-time PRBS checker.
1:1 ROSW 0h 01b: Triggers a scan
Automatically cleared to 0 when the scan
3Ah
PRBS_CTRL_0
completes.
Enable for automatic eye scan using the
PRBS_MON_AUTO_SCAN_
START
Re-time PRBS checker.
0:0 ROSW 0h 01b: Triggers a scan
Automatically cleared to 0 when the scan
completes.
Enable for manual continuous
measurement using the Re-time PRBS
checker. Rising edge clears the error counter
and starts a measurement. Error counting
PRBS_MON_CONTINUOUS_
ENABLE
1:1
RW
continues until
0h PRBS_MON_CONTINUOUS_ENABLE is set to
3Bh
PRBS_CTRL_1
0, at which point the error counter
PRBS_MON_ERROR_COUNT can be read.
The error counter holds its value until any
new scan is started (manual or auto).
PRBS_MON_SOFT_RESET
0:0
RW
0h
When HIGH, the logic in PRBS monitor state
machine is synchronously reset.
Along with
PRBS_MON_MEASUREMENT_TIME,
determines the length of time of a
measurement for a given phase in
automatic or manual timed modes
(PRBS_MON_AUTO_SCAN_START = 1 or
PRBS_MON_MANUAL_START = 1).
Pre-divider value vs. sampling interval:
0000b: 4
PRBS_MON_MEASUREMENT_
PREDIVIDER
7:4
RW
0h
0001b: 8
0010b: 16
0011b: 32
3Ch
PRBS_CTRL_2
0100b: 64
0101b: 128
0110b: 256
0111b: 512
1000b: 1024
1001b: 2048
1010b-1111b: INVALID
PRBS_MON_SAMPLE_
INTERVAL
Controls sampling interval for an error
signal. The sampling interval is
3:0 RW 2h PRBS_MON_SAMPLE_INTERVAL + 1 clock
cycles. The minimum allowable value is 1
(sampling interval of 2).
GS6152
Final Data Sheet
PDS-060984
Rev.2
July 2015
www.semtech.com
69 of 80
Semtech
Proprietary & Confidential