English
Language : 

GS6152 Datasheet, PDF (65/80 Pages) Semtech Corporation – Multi-Rate 6G UHD-SDI
Table 5-1: Register Descriptions - Standard Address Space (Continued)
Address Register Name Parameter Name
Bit
Slice
R/W
Reset
Value
Description
RSVD
15:6 RW 0h Reserved. Do not change.
EYE_MON_CLEAR
Override value for EYE_MON_PRBS_CLEAR.
5:5
RW
0h Only used when
EYE_MON_FORCE_PRBS_CLEAR = 1.
01b: Overrides the EYE_MON_CLEAR output
with the PRBS_MON__CLEAR value
EYE_MON_FORCE_CLEAR
4:4
RW
0h Allows host interface to directly control the
PRBS/eye monitor bypassing the
PRBS_MON_CTRL state machines.
Override value for EYE_MON_PRBS_CLEAR.
EYE_MON_PRBS_CLEAR
3:3
RW
0h Only used when
EYE_MON_FORCE_PRBS_CLEAR = 1.
EYE_MON_
2Bh
CONTROL_
01b: Overrides the EYE_MON_PRBS_CLEAR
REG_6
output with the EYE_MON_PRBS_CLEAR
EYE_MON_PRBS_FORCE_
CLEAR
2:2
RW
0h value
Allows host interface to directly control the
PRBS/eye monitor bypassing the
EYE_MON_CTRL state machines.
EYE_MON_SELECT
Selects which criteria is used to populate the
eye bitmap.
1:1
RW
1h 00b: PRBS7 check
01b: Arbitrary data check
EYE_MON_WINDOW
Sets which portion of the eye is to be
sampled for manually timed and continuous
0:0 RW 0h scan measurements. Result for the phase is
the lesser count of errors at each
EYE_MON_WINDOW setting.
RSVD
15:15 RO
0h Reserved. Do not change.
EYE_MON_PRBS_STARTING_
PHASE
14:8
RO
Starting (leftmost) phase of
EYE_MON_PRBS_EYE_WIDTH in the most
0h recent scan. This parameter only applies to
automatic (AUTO_SCAN_START)
measurements.
2Ch
EYE_MON_
STATUS_REG_0
Widest open portion of the eye in the most
recent scan, based on the
EYE_MON_PRBS_ERROR_COUNT indication.
The value of EYE_MON_PRBS_EYE_WIDTH is
the number of contiguous phases with
EYE_MON_PRBS_EYE_WIDTH 7:0
RO
0h EYE_MON_PRBS_ERROR_COUNT less than
or equal to
EYE_MON_PRBS_ERROR_THRESHOLD.
This parameter only applies to automatic
(AUTO_SCAN_START) measurements.
GS6152
Final Data Sheet
PDS-060984
Rev.2
July 2015
www.semtech.com
65 of 80
Semtech
Proprietary & Confidential