English
Language : 

BU26154MUV_15 Datasheet, PDF (36/90 Pages) Rohm – Monaural Audio CODEC with Touch Panel Interface
BU26154MUV
Datasheet
Auto Operation Mode
When TCHA2 bit of Touch ADC Control register is set to "0", BU26154MUV is set to Auto Operation Mode. When is to set
in Auto Mode Operation, BU 26154 MUV is Interrupt mode by reading to ADCR2 register in 12 bit mode and BU 26154
MUV is Interrupt mode by reading to ADCR1 register in 8 bit mode.
TCLKEN Bit
Internal Clk
I2C Operation
SCL
SDA
Internal ADC Start Sync
ADC Status
IDLE
ADCR1Register
ADCR2 Register
Write Data reception
INDEX=0x61,TCHEN="1"
D2 D1 D0 ACK
Data Hold
Slave address receptio Read Data reception
INDEX=0x64
1 0 R ACK D7 D6 D5
AD Conversion1_1 AD Conversion1_2
Data Valid1_1
IDLE
Data Valid1_2
Interrupt Mode
Tw_ADC1
Tw_ADC2
12Bit Auto Mode I2C Timing
TCLKEN Bit
Internal Clk
I2C Operation
SCL
SDA
Internal ADC Start Sync
ADC Status
IDLE
ADCR1Register
ADCR2 Register
Write Data reception
INDEX=0x61,TCHEN="1"
D2 D1 D0 ACK
Data Hold
AD Conversion1_1
IDLE
Data Valid1_1
Slave address receptio Read Data reception
INDEX=0x62
1 0 R ACK D7 D6 D5
Interrupt Mode
Tw_ADC1
8Bit Auto Mode I2C Timing
TCLKEN Bit
Internal Clk
SPI Operation
SCLK
CSB
Internal ADC Start Sync
ADC Status
IDLE
ADCR1Register
ADCR2 Register
Write Data
INDEX=0x61,TCHEN="1"
Data Hold
Read Data
INDEX = 0x64
AD Conversion1_1 AD Conversion1_2
Data Valid1_1
IDLE
Data Valid1_2
Tw_ADC1
Tw_ADC2
12Bit Auto Mode SPI Timing
Interrupt Mode
www.rohm.com
© 2014 ROHM Co., Ltd. All rights reserved.
TSZ22111 • 15 • 001
36/86
TSZ02201-0V2V0E500110-1-2
26.Oct.2015 Rev.002