slave address reception
Access address reception
SCL Start 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 S
SDA
0 0 1 1 0 1 0 W A A7 A6 A5 A4 A3 A2 A1 A0 A
slave address reception
Read data transmission
Read data transmission
Continued Start 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
from the
above
0 0 1 1 0 1 0 R A D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 D3 D2 D1 D0 A
Internal read
Internal read
Figure 25
If the Master device returns ACK (acknowledge) after the 8 bit data transferred from the LSI becomes continuous read
mode. The next received 8 bits of data will be read from the internal register addressed by incremented by two to the
current address.