5. Electrical Characteristics
5.1.7 Voltage Detector and Power Supply Circuit Electrical Characteristics
Table 5.12 Voltage Detector 0 Electrical Characteristics
The measurement condition is VCC1 = 2.7 to 5.5 V, Topr = -20°C to 85°C/-40°C to 85°C, unless otherwise specified.
Symbol
Parameter
Condition
Standard
Unit
Min. Typ. Max.
Vdet0
Voltage detection level Vdet0_0 (1)
When VCC1 is falling.
1.60 1.90 2.20 V
Voltage detection level Vdet0_2 (1)
When VCC1 is falling.
2.70 2.85 3.15 V
-
Voltage detector 0 response time (3)
When VCC1 falls from 5 V
to (Vdet0_0 - 0.1) V
200 μs
-
Voltage detector self power consumption
VC25 = 1, VCC1 = 5.0 V
1.5
μA
td(E-A)
Waiting time until voltage detector operation
starts (2)
100 μs
Notes:
1. Select the voltage detection level with the VDSEL1 bit in the OFS1 address.
2. Necessary time until the voltage detector operates when setting to 1 again after setting the VC25 bit in the VCR2
register to 0.
3. Time from when passing the Vdet0 until when a voltage monitor 0 reset is generated.
Table 5.13 Voltage Detector 1 Electrical Characteristics
The measurement condition is VCC1 = 2.7 to 5.5 V, Topr = -20°C to 85°C/-40°C to 85°C, unless otherwise specified.
Symbol
Parameter
Condition
Standard
Unit
Min. Typ. Max.
Vdet1
Voltage detection level Vdet1
When VCC is falling
2.95 3.25 3.55 V
-
-
-
td(E-A)
Hysteresis width when VCC1 of voltage detector
1 is rising
Voltage detector 1 response time (2)
When VCC1 falls from 5 V
to (Vdet1_0 - 0.1) V
Voltage detector self power consumption
VC26 = 1, VCC1 = 5.0 V
Waiting time until voltage detector operation
starts (1)
0.15
V
200 μs
1.7
μA
100 μs
Notes:
1. Necessary time until the voltage detector operates when setting to 1 again after setting the VC26 bit in the VCR2
register to 0.
2. Time from when passing the Vdet1 until when a voltage monitor 1 reset is generated.