Section 11 Programmable Pulse Generator (PPG)
11.3.6 Pulse Output Triggered by Input Capture
Pulse output can be triggered by TPU input capture as well as by compare match. If TGRA
functions as an input capture register in the TPU channel selected by PCR, pulse output will be
triggered by the input capture signal.
Figure 11.9 shows the timing of this output.
φ
TIOC pin
Input capture
signal
NDR
N
PODR
M
N
PO
M
N
Figure 11.9 Pulse Output Triggered by Input Capture (Example)