English
Language : 

HYS72T64400HFA Datasheet, PDF (18/47 Pages) Qimonda AG – 240-Pin Fully-Buffered DDR2 SDRAM Modules
Internet Data Sheet
HYS72T[64/128/256]4[00/20]HFA–[2.5/3S/3.7]–B
Fully-Buffered DDR2 SDRAM Modules
TABLE 12
Environmental Parameters
Parameter
Symbol
Rating
Units Notes
Operating Temperature
TOPR
See Note
1)
Operating Humidity (relative)
HOPR
10 to 90
%
2)
Storage Temperature
TSTG
-50 to +100
°C
2)
Storage Humidity (without condensation)
HSTG
5 to 95
%
2)
Barometric pressure (operating)
PBAR
3050
m
2)
Barometric pressure (storage)
PBAR
14240
m
2)
1) The designer must meet the case temperature specifications for individual module components.
2) Stresses greater than those listed may cause permanent damage to the device. This is a stress rating only and the device funcional
operation at or above the conditions indicated is not implied. Exposure to absolute maximum rating conditions for extended periods may
affect reliability.
Rev.1.01, 2007-06-20
18
10062006-RQWY-GI6S