Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
Inverter Part
Collector-Emitter Saturation Voltage
VCE(sat) VD = VDB = 15V, IC = 5A, VIN = 5V, Tj = 25°C
VD = VDB = 15V, IC = 5A, VIN = 5V, Tj = 125°C
Diode Forward Voltage
VEC
-IC = 5A, VIN = 0V
Switching Times
ton
trr
VCC = 300V, VD = VDB = 15V,
tC(on)
IC = 5A, Tj = 125°C,
toff
VIN = 0 ⇔ 5V, Inductive Load
tC(off)
Collector-Emitter Cutoff Current
ICES
VCE = VCES, Tj = 25°C
VCE = VCES, Tj = 125°C
—
—
—
0.75
—
—
—
—
—
—
1.50
1.60
1.70
1.35
0.30
0.35
1.40
0.30
—
—
2.00
2.10
2.20
1.95
—
0.55
2.00
0.60
1.0
10
Volts
Volts
Volts
µs
µs
µs
µs
µs
mA
mA
Control (Protection) Part
Circuit Current ID
VIN = 0V, VD = 15V
Total of VP1-VNC, VN1-VNC
—
—
2.80
mA
VIN = 5V, VD = 15V
Total of VP1-VNC, VN1-VNC
—
—
2.80
mA
IDB VIN = 0V, VD = VDB = 15V Each Part of VUFB-U, VVFB-V, VWFB-W
—
—
0.10
mA
VIN = 5V, VD = VDB = 15V Each Part of VUFB-U, VVFB-V, VWFB-W
—
—
0.10
mA
Fault Output Voltage
VFOH
VSC = 0V, FO Terminal Pull-up to 5V by 10kΩ
4.9
—
—
Volts
VFOL
VSC = 1V, IFO = 1mA
—
—
0.95 Volts
Input Current
IIN
VIN = 5V
0.70
1.00
1.50
mA
Short Circuit Trip Level
VSC(ref)
VD = 15V*4
0.43 0.48 0.53 Volts
Temperature Output
VOT
LVIC Temperature = 90°C
2.63 2.77 2.91 Volts
Pull Down R = 5kΩ*6
LVIC Temperature = 25°C
0.88
1.13
1.39 Volts
Control Supply
UVDBt
Trip Level, Tj ≤ 125°C
7.0
10.0
12.0
Volts
Under-voltage Protection
UVDBr
Reset Level, Tj ≤ 125°C
7.0
10.0
12.0
Volts
UVDt
Trip Level, Tj ≤ 125°C
10.3
—
12.5 Volts
UVDr
Reset Level, Tj ≤ 125°C
10.8
—
13.0 Volts
Fault Output Pulse Width*5
tFO
20
—
—
µs
ON Threshold Voltage
Vth(on)
Applied between
—
2.1
2.6
Volts
OFF Threshold Voltage
Vth(off)
UP, VP, WP-VNC,
0.8
1.3
—
Volts
ON/OFF Threshold Hysteresis Voltage Vth(hys)
UN, VN, WN-VNC
0.35 0.65
—
Volts
Bootstrap Diode Forward Voltage*7
VF
IF = 10mA,
1.1
1.7
2.3
Volts
Including Voltage Drop by Limiting Resistor
Built-in Limiting Resistance
R
For Bootstrap Circuit
80
100
120
Ω
*4 Short Circuit protection is functioning only for N-side IGBTs. Please select the value of the external shunt resistor such that the SC trip level is less than 1.7 times the current rating.
*5 Fault signal, FO, outputs when SC or UV protection works. FO pulse width is different for each protection mode. At SC failure, FO pulse width is a fixed width (=min. 20µs), however, at UV
failure, FO outputs continuously until recovering from UV state. Minimum FO pulse width is 20µs.