HIGH DENSITY 32 CHANNEL T1/E1/J1 FRAMER
Register 0x01D7 System Side SBI Parity Error Interrupt Status
Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R
R
R
R
R
R
R
R
Function
SPE[1]
SPE[0]
TRIB[4]
TRIB[3]
TRIB[2]
TRIB[1]
TRIB[0]
PERRI
Default
X
X
X
X
X
X
X
X
PERRI:
When set PERRI indicates that an SBI parity error has been detected. This
bit is cleared when read.
TRIB[4:0] and SPE[1:0]:
The TRIB[4:0] and SPE[1:0] field are used to specify the SBI tributary for
which a parity error was detected. These fields are only valid only when
PERRI is set.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR THE INTERNAL USE OF ITS CUSTOMERS
296