English
Language : 

PM8610 Datasheet, PDF (205/338 Pages) PMC-Sierra, Inc – SBI Bus Serializer / STS-12 Time Slot Interchange
SBS Telecom Standard Product Data Sheet
Preliminary
Register 089h: PPP Monitor Synchronization Interrupt Status
Bit
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R
R
R
R
R
R
R
R
R
R
R
R
Function
Unused
Unused
Unused
Unused
MON12_SYNCI
MON11_SYNCI
MON10_SYNCI
MON9_SYNCI
MON8_SYNCI
MON7_SYNCI
MON6_SYNCI
MON5_SYNCI
MON4_SYNCI
MON3_SYNCI
MON2_SYNCI
MON1_SYNCI
Default
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
This register reports the PRBS monitor synchronization status change interrupts for all the
time-slots in the Receive Protection Serial Link.
MONx_SYNCI
The Monitor Synchronization Interrupt Status register is set high when a change occurs in the
monitor’s synchronization status. Whenever a state machine of the x STS-1 path goes from
Synchronized to Out Of Synchronization state or vice-versa, the MONx_SYNCI is set high.
This bit is independent of MONx_SYNCE and is cleared after it’s been read.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
205
Document ID: PMC-2000168, Issue 3