English
Language : 

74F821 Datasheet, PDF (10/18 Pages) NXP Semiconductors – Bus interface registers
Philips Semiconductors
Bus interface registers
Product specification
74F821/822/823/824/825/826
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
VCC
VIH
VIL
IIk
IOH
IOL
Tamb
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High–level output current
Low–level output current
Operating free-air temperature range
Commercial range
Industrial range
LIMITS
UNIT
MIN
NOM
MAX
4.5
5.0
5.5
V
2.0
V
0.8
V
–18
mA
–24
mA
64
mA
0
+70
°C
–40
+85
°C
DC ELECTRICAL CHARACTERISTICS
(Over recommended operating free-air temperature range unless otherwise noted.)
SYMBOL
PARAMETER
TEST CONDITIONS1
LIMITS
UNIT
MIN TYP2 MAX
VOH
High-level output voltage
VOL
Low-level output voltage
±10%VCC 2.4
V
VCC = MIN,
VIL = MAX,
IOH = –15mA
±5%VCC
2.4
V
VIH = MIN
±10%VCC 2.0
IOH = –24mA ±5%VCC 2.0
V
V
VCC = MIN,
VIL = MAX,
VIH = MIN
IOL = MAX
±10%VCC
±5%VCC
0.55 V
0.42 0.55 V
VIK
II
IIH
IIL
IOZH
IOZL
IOS
Input clamp voltage
Input current at maximum input voltage
High–level input current
Low–level input current
Off–state output current, high–level voltage applied
Off–state output current, low–level voltage applied
Short–circuit output current3
74F821,
74F822
ICCH
ICCL
ICCZ
VCC = MIN, II = IIK
VCC = 0.0V, VI = 7.0V
VCC = MAX, VI = 2.7V
VCC = MAX, VI = 0.5V
VCC = MAX, VO = 2.7V
VCC = MAX, VO = 0.5V
VCC = MAX
VCC = MAX
–0.73 –1.2 V
100 µA
20 µA
–20 µA
50 µA
–50 µA
-100
-225 mA
75 105 mA
75 105 mA
75 115 mA
ICC
Supply current (total)
74F823,
74F824
ICCH
ICCL
ICCZ
VCC = MAX
65 100 mA
70 105 mA
75 110 mA
74F825,
74F826
ICCH
ICCL
VCC = MAX
60
85 mA
60
90 mA
ICCZ
65
95 mA
NOTES:
1. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions for the applicable type.
2. All typical values are at VCC = 5V, Tamb = 25°C.
3. Not more than one output should be shorted at a time. For testing IOS, the use of high-speed test apparatus and/or sample-and-hold
techniques are preferable in order to minimize internal heating and more accurately reflect operational values. Otherwise, prolonged shorting
of a high output may raise the chip temperature well above normal and thereby cause invalid readings in other parameter tests. In any
sequence of parameter tests, IOS tests should be performed last.
1996 Jan 05
10