AMIS-30621 Datasheet, PDF (2/59 Pages) AMI SEMICONDUCTOR – LIN Microstepping Motordriver | |||
|
◁ |
AMISâ30621
APPLICATIONS
The AMISâ30621 is ideally suited for small positioning
applications. Target markets include: automotive (headlamp
alignment, HVAC, idle control, cruise control), industrial
equipment (lighting, fluid control, labeling, process control,
XYZ tables, robots...) and building automation (HVAC,
surveillance, satellite dish, renewable energy systems).
Suitable applications typically have multiple axes or require
mechatronic solutions with the driver chip mounted directly
on the motor.
Table 1. ORDERING INFORMATION
Part No.
Peak Current
UV*
Package
Shippingâ
AMIS30621C6213G
AMIS30621C6213RG
800 mA
800 mA
High
High
SOICâ20
(PbâFree)
Tube / Tray
Tape & Reel
AMIS30621C6216G
AMIS30621C6216RG
800 mA
800 mA
Low
NQFPâ32 (7 x 7 mm)
Low
(PbâFree)
Tube / Tray
Tape & Reel
AMIS30621C6217G**
800 mA
Low
AMIS30621C6217RG**
800 mA
Low
SOICâ20
(PbâFree)
Tube / Tray
Tape & Reel
â For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specification Brochure, BRD8011/D.
*UV undervoltage lock out levels: see DC Parameters UV1 & UV2 (Stop Voltage thresholds).
** For prodcut versions AMIS30621C6217G and AMIS30621C6217RG the Ihold0 bit in OTP is programmed to â1â.
QUICK REFERENCE DATA
Table 2. ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Min
Max
Unit
VBB, VHW2, VSWI Supply voltage, Hardwired Address and SWI Pins
â0.3
+40
V
(Note 1)
Vlin
Bus input voltage
â40
+40
V
TJ
Junction temperature range (Note 2)
â50
+175
°C
Tst
Storage temperature
â55
+160
°C
Vesd
Human Body Model Electrostatic discharge voltage on LIN
â4
+4
kV
pin (Note 3)
Human Body Model Electrostatic discharge voltage on other
â2
+2
kV
pins (Note 3)
CDM Electrostatic discharge voltage on other pins (Note 4)
â500
+500
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. For limited time: VBB < 0.5 s, SWI and HW2 pins < 1.0 s.
2. The circuit functionality is not guaranteed.
3. Human Body Model according to MILâSTDâ883 Method 3015.7, measured on SOIC devices, and according to AECâQ100:
EIAâJESD22âA114âB (100 pF via 1.5 kW) measured on NQFP device.
4. CDM according to EOS_ESDâDS5.3â1993 (draft)âsocketed mode, measured on SOIC devices, and according to AECâQ100:
EIAâJESD22âA115âA measured on NQFP devices.
Table 3. OPERATING RANGES
Symbol
Parameter
Min
Max
Unit
VBB
Supply voltage
+6.5
+29
V
TJ
Operating temperature range (Note 5)
â40
+165
°C
5. Note that the thermal warning and shutdown will get active at the level specified in the âDC Parametersâ. No more than 100 cumulated hours
in life time above Ttw.
http://onsemi.com