English
Language : 

Y92S-41-200 Datasheet, PDF (9/32 Pages) Omron Electronics LLC – This Compact Cam Positioner, Popular for Its Ease-of-use, Now Comes with Even Better Functions.
H8PS
■ Input Connections
Only the Encoder inputs are connected with 8-output Models. The inputs are no-voltage (short-circuit or open) inputs.
No-voltage Inputs
Open Collector
PLC,
sensor,
etc.
Contact Input
Voltage-output sensors can also be connected.
Connection Examples
Sensor, etc.
H8PS-16@
H8PS-32@
6 7 8 9 10 11
Note: Operates when the transistor turns ON.
H8PS-16@
H8PS-32@
6 7 8 9 10 11
Note: Operates when the contact turns ON.
H8PS-16@
H8PS-32@
6 7 8 9 10 11
Note: Operates when the transistor turns ON.
No-voltage Input Signal Levels
No-contact inputs
Contact inputs
Short-circuit level for transistor ON
• Residual voltage: 2 V max.
• Impedance when ON: 1 kΩ max.
(The leakage current is approx. 2 mA
when the impedance is 0 Ω.)
Open level for transistor OFF
• Impedance when OFF: 100 kΩ min.
Use a contact that can adequately switch
2 mA at 5 V.
Note: Use a maximum DC power supply of 30 V.
■ Output Connections
Note: Internal circuit damage may result from a short circuit in the load.
NPN Output Models
Outputs
Load
PNP Output Models
Vs (See note 2.)
(See note.)
COM/(−)
Note: Always connect a diode to absorb
counter-electromotive force when
connecting an inductive load.
Item
Output method
Dielectric strength
Rated current
Residual voltage
Leakage current
Cam outputs,
RUN output
NPN open collector
30 VDC
100 mA (See note.)
2 VDC max.
100 µA max.
Pulse output
30 mA
0.5 VDC max.
5 µA max.
Note: Do not exceed 1.6 A total for all cam outputs and the RUN
output.
Outputs
Load (See note 1.)
COM/(−)
Note: 1. Always connect a diode to absorb counter-electromotive force when
connecting an inductive load.
2. The VS terminal and power supply terminals are not connected internally.
Item
Output method
Dielectric strength
Rated current
Residual voltage
Leakage current
Cam outputs,
RUN output
Pulse output
PNP open collector
8-output Models: 30 VDC
16-/32-output Models: 26.4 VDC
100 mA (See note.) 30 mA
2 VDC max.
100 µA max.
Note: Do not exceed 1.6 A total for all cam outputs and the RUN
output.
9