English
Language : 

Y92S-41-200 Datasheet, PDF (11/32 Pages) Omron Electronics LLC – This Compact Cam Positioner, Popular for Its Ease-of-use, Now Comes with Even Better Functions.
Nomenclature
■ Displays
8-output Models
(1) Cam output indicators
(2) PV/SV indicator
12345678
PRG
TST
RUN
(4) Rotation display
monitor
(6) Cam No. display
CAM
STEP
(7) Step No. display
16-/32-output Models
(1) Cam output indicators
(2) PV/SV indicator
(3) Start input
indication
(4) Rotation display
monitor
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32
PRG
TST
RUN
(5) Bank No. display
(6) Cam No. display
(7) Step No. display
CAM
STEP
■ Operation Keys
8-output Models
CHECK
CAM
STEP
11. ADV key
CAM
STEP
12. Mode switch
ADV
ON
OFF
13. Programming
mode switch
14. Rotation direction
switch
15. Encoder resolution
switch
PRGM
TEST
RUN
TCH
MAN
CW
1234
3 4 PLS/R
ON
OFF
ON ON 256
ON OFF 256
OFF ON 360
OFF OFF 720
CCW DO NOT USE.
ANG
DSPL
256
360
360
360
ANGLE
WRITE
ORIGIN CLEAR
16-/32-output Models
CHECK
CAM
STEP
11. ADV key
12. Mode switch
13. Programming
mode switch
14. Rotation direction
switch
15. Encoder resolution
switch
CAM
STEP
PRGM
TEST
RUN
TCH
MAN
ADV
BANK
ANGLE
ON
OFF
WRITE
CW
1234
3 4 PLS/R
ON
OFF
ON ON 256
ON OFF 256
OFF ON 360
OFF OFF 720
CCW DO NOT USE.
ANG
DSPL
256
360
360
360
ORIGIN CLEAR
H8PS
(8) All protect
indication
(9) Mode indicator
(10) Main display
(11) Unit indication
(12) 256 indication
(13) Unit indication
(14) Sub-display
(15) ON/OFF
indication
(16) ADV indication
(8) All protect
indication
(9) Mode indicator
(10) Main display
(11) Unit indication
(12) 256 indication
(13) Unit indication
(14) Sub-display
(15) ON/OFF
indication
(16) ADV indication
Display Details
No. Display
color
Description
(1) Orange Lit while cam outputs are ON.
(2) Red
PV: Lit while the present angular position or speed is displayed in
main display.
SV: Lit while the setting value is displayed in main display.
(3) Orange Lit while the start input is ON in Run or Test Mode.
Not lit when an error occurs.
(4) Orange Displays Encoder present angular position, direction, and speed
guidelines.
(5) Green Displays the bank number that is running in Run or Test Mode and
the bank number selected in Programming Mode.
(6) Green Displays the cam number for the angle setting displayed on sub-
display.
(7) Green Displays the step number for the angle setting displayed on sub-
display.
(8) Orange Lit while the All Protection function is enabled.
(9) Orange The indicator for the selected mode is lit.
PRG: Programming Mode
TST: Test Mode
RUN: Run Mode
(10) Red
Displays the present angular position or the speed and settings
being made.
(11) Red Displays units for the angle or the speed displayed on main display.
(12) Red
Lit while using an Encoder with a resolution of 256 if 256° display is
selected.
(13) Green Displays units for the angle or the speed displayed on sub-display.
(14) Green Displays the speed or the ON/OFF angle settings.
(15) Green Indicates whether main display displays the ON or OFF angle
setting.
(16) Green Lit while setting the Advance Angle Compensation (ADV) Function.
1. CHECK key
2. CAM keys
3. STEP keys
5. ON/OFF key
6. WRITE key
7. ANGLE keys
9. CLEAR key
10. ORIGIN key
1. CHECK key
2. CAM keys
3. STEP keys
4. BANK key
5. ON/OFF key
6. WRITE key
7. ANGLE keys
8. USB connector
9. CLEAR key
10. ORIGIN key
Operation Key Details
No.
Description
1 Displays program details in Run Mode.
2 Selects the cam number with
Keys.
3 Selects the step number with
Keys.
4 Selects the bank number.
5 Selects the ON angle, or OFF angle
6 Writes the set data to memory.
7 Changes the angle or other setting value with
Keys.
8 Connects the Cam Positioner to a personal computer via USB cable (order
separately) for programming with the Support Software (order separately).
9 Moves to the screen for clearing settings
10 Designates the current angle of the machine (Encoder) as the origin (0°).
11 Programming or Test Mode: Press to shift to the ADV function setting
screen.
Programming Mode: Press and hold at least 3 s to shift to the Function
Setting Mode.
Run Mode: Press and hold at least 5 s to enable/disable the All Protection
function.
12 Switches modes.
Programming Mode (PRGM):
Used to write cam programs, set the ADV function,
etc.
Test Mode (TEST): Used to modify settings while the Encoder is running.
Run Mode (RUN): Used for normal operation and to check the cam
program.
13 Select the method used for programming cams.
Teaching: ON/OFF Angles can be set based on actual machine (Encoder)
operation.
Manual: ANGLE Keys can be used to set ON/OFF angles.
14 Sets the H8PS rotation direction (rotation display monitor, etc.) to the
machine (Encoder) rotation direction.
15 Sets the resolution of the connected Encoder.
Also sets the unit for angle display when using an Encoder with a
resolution of 256.
11