English
Language : 

Y92S-27 Datasheet, PDF (47/61 Pages) Omron Electronics LLC – DIN 48 x 48-mm Multifunctional Timer Series
H3CR-H
Operation
■ Timing Chart
t: Set time
Rt: Minimum power ON time (S-series: 0.1 s min.; M-series: 2 s min.)
If the power ON time is less than this value, the Timer may not operate (i.e., output may not turn ON).
Model
H3CR-H8L
Power
ON
(See note) OFF
Timing chart
Rt
t
Rt
t
Output (1 − 3)
Output (1 − 4)
Output (8 − 6)
H3CR-H8RL
Output (8 − 5)
Output
indicator
Lit
Not lit
Power
(See note)
ON
OFF
Reset input ON (Short-circuited)
OFF (Open)
Output (8 − 6)
Rt
t
0.05 s min.
Rt
t
0.05 s min.
H3CR-HRL
Output (8 − 5)
Output
indicator
Lit
Not lit
Power
ON
(See note) OFF
Reset input
Rt
t
0.05 s
min.
Rt
t
0.05 s min.
Output (1 − 3)
Output (1 − 4)
Output (11 − 9)
Output (11 − 8)
Output
indicator
Lit
Not lit
Note: If the power is turned ON until the set time is up, the timer will be retriggered.