Application Examples (H3CR-A)
H3CR-A
A Mode: ON-delay
ON-delay operation (A mode) is a basic mode.
1. Power-ON Start/Power-OFF Reset
The Power-ON start/Power-OFF reset operation is a standard
operating method.
t
Power (2 and 10)
Start (2 and 6)
Reset (2 and 7)
Control output: NC (8 and 11)
NC (1 and 4)
Control output: NO (9 and 11)
NO (1 and 3)
Power indicator
Flashing
Lit
Externally short-circuited
3. Control of Integrated Time with Gate
Signal
Gate signal processing (during input or a temporary timing stop) is
possible with both power start and signal start.
Power (2 and 10)
t1
t2
t1 + t2: set time
Start (2 and 6)
Gate (2 and 5)
Control output: NC (8 and 11)
NC (1 and 4)
Control output: NO (9 and 11)
NO (1 and 3)
Power indicator
Flashing
Lit
Gate signal (The operation is interrupted with the
gate signal if the Timer detects an abnormal signal.)
Power
supply
2. Signal Start/Signal Reset
The Signal start/Signal reset operation is useful for remote control of
the Timer.
Power (2 and 10)
Start (2 and 6)
Reset (2 and 7)
Control output: NC (8 and 11)
NC (1 and 4)
Control output: NO (9 and 11)
NO (1 and 3)
Power indicator
Lit
Flashing
Lit
Start signal (remote control possible)
Reset signal
(remote control possible)
Power
supply
(Power continuously supplied)
Externally
short-circuited
Power
supply
B/B2 Mode: Flicker
The flicker operation in the B and B2 modes can be effectively
applied to lamp or buzzer (ON and OFF) alarms or the monitoring of
an intermittent operation with a display.
1. Power-ON Start/Power-OFF Reset (in B
Mode)
Power (2 and 10)
Start (2 and 6)
Control output: NC (8 and 11)
NC (1 and 4)
Control output: NO (9 and 11)
NO (1 and 3)
Power indicator
Flashing
Externally short-circuited
Power
supply