English
Language : 

S8VS Datasheet, PDF (14/24 Pages) Omron Electronics LLC – Switch mode Power Supply (Visible and Slim New Din Rail Power Supply)
Specifications
I Ratings/Characteristics
Item
Efficiency (typical)
Input
Voltage
Frequency
Current (see note 1)
Output
Additional
function
Other
Power factor (see note 1)
Leakage current (see note 1)
Inrush current (25°C, cold start) (see note 1)
Voltage adjustment range
Ripple (see note 1)
Input variation influence
Load variation influence
Temperature variation influence (see note 1)
Rise time
Hold time (see note 1)
Overload protection
Overvoltage protection
Overheat protection
Protection-ON alarm indicator
Parallel operation
Heat radiation
Ambient temperature
Ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Terminal screw tightening torque
Electromagnetic interference
EMC
Approved standards
Reliability (MTBF) (see note 3)
Life expectancy (see note 4)
Weight (see note 5)
Mounting method
50 W
100 W
150 W
300 W
600 W
75 to 87% (depends on the model)
100 to 240 VAC (85 to 264 VAC)
47 to 450 Hz
0.9 or 0.45 A 1.8 or 0.9 A
max.
max.
2.7 or 1.4 A
max.
5.4 or 2.7 A
max.
10 or 5 A max.
0.95 TYP.
0.5 or 1.0 mA max.
25 or 50 A max.
−5% to 10%
2% (p-p) max.
0.4% max. (at 85 to 132 VAC input/at 170 to 264 VAC input, 100% load)
0.8% max. (with rated input, 0 to 100% load)
0.05%/°C max.
1,000 ms max. (up to 90% of output voltage at rated output voltage/current)
20 ms min.
105% min., voltage trailing intermittent operation
(With the 600-W model, output is turned OFF at 5 s min.)
Yes
No
Yes
No
Yes (Red)
No
Yes, 2 units max.
Natural air-cooling
Fan
Operating: See the derating curve in the Engineering Data section. (with no condensation
nor icing)
Storage: −25°C to 65°C (with no condensation nor icing)
25% to 85%
3.0 kVAC, 50/60 Hz for 1 min (between all inputs and outputs)
2.2 kVAC, 50/60 Hz for 1 min (between all inputs and GR terminals)
1 kVAC, 50/60 Hz for 1 min (between all outputs and GR terminals)
100 MΩ min. (between all output and input/GR terminals at 500 VDC)
10 to 55 Hz, 0.75-mm amplitude for 2 h each in X, Y, and Z directions
300 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Yes (green)
1.08 N·m (see note 2)
Conforms to FCC Class B, EN50081-1
(EMI):
Emission Enclosure:
Emission AC Mains:
Harmonic Current:
(EMS):
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
EN50081-1
EN55022 class B
EN55022 class B
EN61000-3-2
EN50082-2
EN61000-4-2: 4-kV contact discharge (level 2)
8-kV air discharge (level 3)
ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
ENV50141: 10 V (0.15 to 80 MHz) (level 3)
EN61000-4-4: 2-kV power-line (level 3)
2-kV output line (level 4)
EN61000-4-5: between 3-kV lines
between 4.5-kV line and FG
UL508, UL1012, CSA C22.2 No. 950, CSA C22.2 No. 14, EN60950, VDE0160.
Conforms to UL1950 and CSA E.B. 1402C
135,000 hrs min.
60,000 hrs min.
10 yrs. min. (Used at 40°C at the rated input with a 50% load, standard installation)
420 g max.
600 g max.
900 g max.
2,200 g max. 3,500 g max.
Front-mounting Bracket or DIN Track Mounting Bracket
Front-mounting Bracket
Note: 1. 100% load for rated input voltage (100 VAC or 200 VAC)
2. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals.
3. MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates
reliability of devices. Therefore, it does not necessarily represent a life of the product.
4. The life expectancy shown in the above table indicates average operating hours under the ambient temperature of 40°C and a load rate
of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. It must be noted that the life
expectancy of the fan built into the 600-W model is not included.
5. The weight indicated is for the open-frame type. (Includes the cover for 300-W and 600-W models.)
L-68
Switch mode Power Supply S8PS