DS92LV3221 Datasheet, PDF (9/24 Pages) National Semiconductor (TI) – 20-50 MHz 32-Bit Channel Link II Serializer / Deserializer
Deserializer Switching Characteristics
Over recommended operating supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max Units
tROCP
Receiver Output Clock Period
tROCP = tCIP
Figure 9
20
tROCP
50
ns
tRODC
tROTR
tROTF
RxCLKOUT Duty Cycle
LVCMOS Low-to-High Transition
Time
LVCMOS High-to-Low Transition
Time
CL = 8pF
(lumped load)
Figure 8
45
50
55
%
3.2
ns
3.5
ns
tROSC
tROHC
tHZR
RxOUT[31:0] Setup to RxCLKOUT f = 50 MHz
RxOUT[31:0] Hold to RxCLKOUT
Data Output High to TRI-STATE® Figure 11
Delay
0.5 x
5.6
tROCP
ns
0.5 x
7.4
tROCP
ns
5
10
ns
tLZR
Data Output Low to TRI-STATE®
Delay
5
10
ns
tZHR
Data Output TRI-STATE® to High
Delay
5
10
ns
tZLR
Data Output TRI-STATE® to Low
Delay
5
10
ns
tRD
Deserializer Porpagation Delay –
Latency
f = 20 MHz
Figure 10
5.5 x
ns
tROCP +
3.35
f = 50 MHz
5.5 x
ns
tROCP +
6.00
tRPLLS
Deserializer PLL Lock Time
20 MHz – 50 MHz
Figure 11
(Note 5)
128k x
tROCP
ns
TOLJIT
tLVSKR
Deserializer Input Jitter Tolerance
LVDS Differential Input Skew
Tolerance
20 MHz – 50 MHz
Figure 15
0.25
UI
0.4 x
tROCP
ns
Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur, including inoperability and degradation of device reliability
and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or other conditions beyond those indicated in
the Recommended Operating Conditions is not implied. The Recommended Operating Conditions indicate conditions at which the device is functional and the
device should not be operated beyond such conditions.
Note 2: Typical values represent most likely parametric norms at VDD = 3.3V, TA = +25°C, and at the Recommended Operating Conditions at the time of product
characterization and are not guaranteed.
Note 3: Current into a the device is defined as positive. Current out of a device pin is defined as negative. Voltages are referenced to ground except VOD,
ΔVOD, VTH, VTL which are differential voltages.
Note 4: When the Serializer output is at TRI-STATE® the Deserializer will lose PLL lock. Resynchronization MUST occur before data transfer.
Note 5: tRPLLS is the time required by the Deserializer to obtain lock when exiting power-down mode.
9