English
Language : 

PC28F00BP30EFA Datasheet, PDF (26/86 Pages) Micron Technology – Numonyx® Axcell™ P30-65nm Flash Memory
P30-65nm
8.3.1
With adequate continuity testing, programming equipment can rely on the WSM’s
internal verification to ensure that the device has programmed properly. This eliminates
the external post-program verification and its associated overhead.
BEFP Requirements and Considerations
Table 10: BEFP Requirements
Parameter/Issue
Case Temperature
VCC
VPP
Setup and Confirm
Programming
Buffer Alignment
Requirement
Notes
TC = 30°C ± 10°C
-
Nominal Vcc
-
Driven to VPPH
-
Target block must be unlocked before issuing the BEFP Setup and Confirm commands. -
The first-word address (WA0) of the block to be programmed must be held constant
from the setup phase through all data streaming into the target block, until transition -
to the exit phase is desired.
WA0 must align with the start of an array buffer boundary.
1
Note: Word buffer boundaries in the array are determined by A[9:1] (0x000 through 0x1FF). The alignment start point is A[9:1]
= 0x000.
Table 11: BEFP Considerations
Parameter/Issue
Cycling
Programming blocks
Suspend
Programming the flash
memory array
Requirement
For optimum performance, cycling must be limited below 50 erase cycles per block.
BEFP programs one block at a time; all buffer data must fall within a single block.
BEFP cannot be suspended.
Programming to the flash memory array can occur only when the buffer is full.
Notes
1
2
-
3
Notes:
1.
Some degradation in performance may occur is this limit is exceeded, but the internal algorithm continues to work
properly.
2.
If the internal address counter increments beyond the block’s maximum address, addressing wraps around to the
beginning of the block.
3.
If the number of words is less than 512, remaining locations must be filled with 0xFFFF.
8.3.2
BEFP Setup Phase
After receiving the BEFP Setup and Confirm command sequence, Status Register bit
SR.7 (Ready) is cleared, indicating that the WSM is busy with BEFP algorithm startup. A
delay before checking SR.7 is required to allow the WSM enough time to perform all of
its setups and checks (Block-Lock status, VPP level, etc.). If an error is detected, SR.4
is set and BEFP operation terminates. If the block was found to be locked, SR.1 is also
set. SR.3 is set if the error occurred due to an incorrect VPP level.
Note:
Reading from the device after the BEFP Setup and Confirm command sequence outputs
Status Register data. Do not issue the Read Status Register command; it will be
interpreted as data to be loaded into the buffer.
Datasheet
26
Sept 2012
Order Number: 208042-06