English
Language : 

DS51795A Datasheet, PDF (46/98 Pages) Microchip Technology – PICkit™ 3 Programmer/Debugger
PICkit™ 3 User’s Guide
PK3Err0012: Download debug exec failed
If you receive this error while attempting to program from the Debugger menu:
1. Deselect the debugger as the debug tool.
2. Close your project and then close MPLAB IDE.
3. Restart MPLAB IDE and re-open your project.
4. Reselect the debugger as your debug tool and attempt to program your
target device again.
If this does not work, see Section 8.3.4 “Corrupted Installation Actions”.
PK3Err0013: NMMR register write failed.
PK3Err0014: File register write failed.
See Section 8.3.2 “Debugger-to-Target Communication Error Actions”.
PK3Err0015: Data transfer was unsuccessful. %d byte(s) expected, %d byte(s)
transferred.
See Section 8.3.3 “Debugger-to-PC Communication Error Actions”.
PK3Err0016: Cannot transmit. PICkit 3 not found.
The debugger is not connected to the PC.
PK3Err0017: File register read failed.
PK3Err0018: NMMR register read failed.
PK3Err0019: Failed while reading emulation registers.
PK3Err0020: Failed while writing emulation registers.
See Section 8.3.2 “Debugger-to-Target Communication Error Actions”.
PK3Err0021: Command not echoed properly. Sent %x, received %x.
PK3Err0022: Failed to get PICkit 3 version information.
PK3Err0024: Download RS failed.
PK3Err0025: Download AP failed.
See Section 8.3.3 “Debugger-to-PC Communication Error Actions”.
PK3Err0026: Download program exec failed.
If you receive this error while attempting to program from the Debugger menu:
1. Deselect the debugger as the debug tool.
2. Close your project and then close MPLAB IDE.
3. Restart MPLAB IDE and re-open your project.
4. Reselect the debugger as your debug tool and attempt to program your
target device again.
If this does not work, see Section 8.3.4 “Corrupted Installation Actions”.
PK3Err0027: Bulk transfer failed due to invalid checksum
See Section 8.3.3 “Debugger-to-PC Communication Error Actions”.
Also, ensure that the cables used are the correct length.
PK3Err0028: Download device database failed
If you receive this error:
1. Try downloading again. It may be a one-time error.
2. Try manually downloading. Select Debugger>Settings, Configuration tab,
and click Manual Download. Select the highest number .jam file and click
Open.
DS51795A-page 42
© 2009 Microchip Technology Inc.