English
Language : 

MLX90365 Datasheet, PDF (9/35 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor IC
MLX90365
Triaxis® Position Sensor IC
Passive Diagnostic Output
Level
(Broken Track Diagnostic) (5)
Clamped Output Level
BVSSPD6
BVSSPU
BVDDPD
BVDDPU
Clamp_lo
Clamp_hi
Broken VSS &
Pull-down load RL ≥ 5 kΩ
Pull-down load RL ≥ 10 kΩ
Broken VSS &
Pull-up load RL ≥ 1kΩ
Broken VDD &
Pull-down load RL ≥ 1kΩ
Broken VDD &
Pull-up load RL ≥ 5kΩ
Programmable
Programmable
97.5 98.5
95
97.5
99.5 100
0
0
0
%VDD
%VDD
0.5
%VDD
2
%VDD
100 %VDD(7)
100 %VDD(7)
As an illustration of the previous table, the MLX90365 fits the typical classification of the output span
described on the Figure 6.
100 %
90 %
80 %
96 %
92 %
88 %
Diagnostic Band (High)
Clamping High
70 %
60 %
50 %
Linear Range
40 %
30 %
20 %
10 %
0%
12 %
8%
4%
Clamping Low
Diagnostic Band (Low)
Figure 6 – Example of Output Span Classification for typical application.
5 For detailed information on diagnostics, see also section 15
6 In case the dual-die variant is used BVssPD level can be influenced. Refer to Technical note MLX90365_Broken_Vss_DualDie
7 Clamping levels need to be considered vs the saturation of the output stage (see Vsat_lo and Vsat_hi)
MLX90365
Rev. 5.7
Page 9 of 35
Datasheet
Jan. 22, 16