Figure 12 - Noise response of the different filter
14.7. Programmable Diagnostic Settings
14.7.1. DIAG mode
Defines the Output Stage mode in case of Diag.
DIAG
mode [2:0]
0
5
6
7
Type
Disable
Digital
Digital
Digital
Descriptions
Output HiZ
open drain NMOS
open drain PMOS
Push-Pull
Comments
Not recommended
14.7.2. DIAG Level
Determines the reporting level (diagnostic low, diagnostic high) during start-up (both analog and PWM
mode), or during a fault reporting (Only in Analog mode).
In PWM mode, the fault reporting level shall in principle be 0 when the leading edge is a rising edge,
(resp. 1 for a falling edge) in order to detect the first cycle after start-up. MLX recommends then
DIAG Level = PWMPOL.