English
Language : 

MLX90365 Datasheet, PDF (10/35 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor IC
MLX90365
Triaxis® Position Sensor IC
8. MLX90365 Isolation Specification
DC Operating Parameters at Nominal Supply Voltage (unless otherwise specified) and for TA as specified
by the Temperature suffix (E or K or L). Only valid for the package code GO i.e. dual die version.
Parameter
Isolation Resistance
Symbol
Test Conditions
Between 2 dies
Min Typ Max
4
Units
MΩ
9. MLX90365 Timing Specification
ANALOG OUTPUT - DC Operating Parameters at Nominal Supply Voltage (unless otherwise specified)
and for TA as specified by the Temperature suffix (E or K or L).
Parameter
Symbol
Test Conditions
Main Clock Frequency
Ck All contributors included thermal
drift
Main Clock Frequency Thermal
Drift
∆TCk
Refresh Rate
Step Response Time
Ts
Filter=0(8)
Filter=1
Filter=2
Watchdog
Twd
Start-up Cycle
Tsu Analog OUT Slew-rate excluded
Analog OUT Slew-rate
Mode 1
from COUT = 47 nF to 330 nF
Mode 2
up to COUT = 10 nF
Mode 3
up to COUT = 47 nF
Mode 4
up to COUT = 330 nF
Min Typ Max
12.6 13.3 14
275
114.5
25
290
657(9)
876
1095
118
37
± 3%
305
896
1195
1494
121.5
5
300 320
17
19
1.8
2.5
Units
MHz
CkNOM
µs
µs
ms
ms
V/ms
8 See section 14.6 for details concerning Filter parameter
9 This represents a theoretical average response time
MLX90365
Rev. 5.7
Page 10 of 35
Datasheet
Jan. 22, 16