English
Language : 

MLX90365 Datasheet, PDF (14/35 Pages) Melexis Microelectronic Systems – Triaxis® Position Sensor IC
MLX90365
Triaxis® Position Sensor IC
Jitter is defined by ± 3 σ for 1000 successive acquisitions with clamped output, see also jitter definition.
Parameter
PWM TON, Tperiod
Rise time, Fall time
Jitter
Duty Cycle
Symbol
Test Conditions
TON
TPWM
Trigger level = 50 % Vpp
10% and 90% of amplitude
J on
J period
% DC
± 3 σ for 1000 successive acquisitions
Ton / TPeriod
Figure 7 – MLX90365 PWM measurement conditions.
MLX90365
Rev. 5.7
Page 14 of 35
Datasheet
Jan. 22, 16