14.2.5. 17-Pts LNR Parameters
The LNR parameters, together with the clamping values, fully define the relation (the transfer function)
between the digital angle and the output signal.
The shape of the MLX90365 transfer function from the digital angle value to the output voltage is
described by the drawing below. In the 16-Pts mode, the output transfer characteristic is Piece-Wise-
Linear (PWL).
Figure 10 - Input range from 65.5°up to 360°
All the Y-coordinates can be programmed from -50% up to +150% to allow clamping in the middle of one
segment (like on the figure), but the output value is limited to CLAMPLOW and CLAMPHIGH values.
Between two consecutive points, the output characteristic is interpolated.
The parameter W determines the input range on which the 17 points (16 segments) are uniformly spread:
W
0 (0000b)
1
2
3
4
5
6
Range
360.0deg
320.0deg
288.0deg
261.8deg
240.0deg
221.5deg
205.7deg
7
192.0deg
∆x
22.5deg
20.0deg
18.0deg
16.4deg
15.0deg
13.8deg
12.9deg
12.0deg
W
8
9
10
11
12
13
14
15
(1111b)
Range
180.0deg
144.0deg
120.0deg
102.9deg
90.0deg
80.0deg
72.0deg
65.5deg
∆x
11.3deg
9.0deg
7.5deg
6.4deg
5.6deg
5.0deg
4.5deg
4.1deg
Outside of the selected range, the output will remain in clamping levels.
MLX90365
Rev. 5.7
Page 20 of 35
Datasheet
Jan. 22, 16