7. MLX90365 Electrical Specification
Operating Parameters at Nominal Supply Voltage (unless otherwise specified) and for TA as specified by
the Temperature suffix (E or K or L).
Parameter
Symbol
Test Conditions
Min Typ Max Units
Nominal Supply Voltage
VDD
4.5
5
5.5
V
Supply Current(2)
Power saving Enabled, All modes
Idd
For Outmode=1
Power saving Disabled, All modes
For Outmode=1
10(3)
6
10(3)
mA
12
8
12
Isurge Current(4)
Isurge
20
mA
Power-On reset ( rising )
HPOR_LH Refer to internal voltage Vdig
2 2.25 2.5
V
Power-On reset Hysteresis HPOR_Hyst
50
200
mV
Start-up Level ( rising )
MT4V LH
3.8 4.0
4.2
V
Start-up Hysteresis
MT4V Hyst
50
200
mV
PTC Entry Level ( rising )
MT7V_LH
5.8 6.2
6.6
V
PTC Entry Level Hysteresis MT7V_Hyst
50
200
mV
Output Short Circuit Current
Output Load Analog
Vout = 0 V
Ishort
Vout = 5 V
Vout = 18 V (TA = 25°C)
Pull-down to Ground
RL
Pull-up to 5V
15
mA
15
mA
18
mA
4.7 10
∞
kΩ
4.7 10
∞
kΩ
Pull-down to Ground
1
Output Load PWM
RL_PWM Pull-up to 5V
1
kΩ
kΩ
Analog Saturation Output Level
Vsat_lo
Vsat_hi
Pull-up load RL ≥ 10 kΩ to 5 V
Pull-up load RL ≥ 5 kΩ to 18V
Pull-down load RL ≥ 5 kΩ
Pull-down load RL ≥ 10 kΩ
0.5
2
2
3
%VDD
95
97
97.5 98.5
%VDD
Pull-up load RL_PWM ≤ 1 kΩ to 5V
98
Digital Saturation Level
Open drain Output
(RL_PWM to Vbat)
Pull-up load RL_PWM ≤ 1 kΩ to 14V
95
Vo_min
Pull-up load RL_PWM ≤ 1 kΩ to 18V
Pull-up load RL_PWM ≤ 5.6 kΩ to 5V
90
96
Pull-up load RL_PWM ≤ 5.6 kΩ to 14V 85
%Vbat
Pull-up load RL_PWM ≤ 5.6 kΩ to 18V 73
Dsat_lo Pull-up load RL ≥ 10 kΩ to 5 V
Active Diagnostic Output Level
Pull-up load RL ≥ 5 kΩ to 18V
0.5
2
2
3
%VDD
Digital Saturation Output Level Dsat_hi Pull-down load RL ≥ 5 kΩPull-down
95
97
load RL ≥ 10 kΩ
%VDD
2 For the dual version, the supply current is multiplied by 2.
3 To reach 10mA, the power saving optionshould be enabled. This option switches off and on internal blocks dynamically. It can
be disabled in case of extreme emission requirements or if an analog output is required with a resistor on either supply or output
line. .