5. Absolute Maximum Ratings
Parameter
Supply Voltage, VDD (overvoltage)
Reverse Voltage Protection
Positive Output Voltage – Standard Version
(Analog or PWM)
Positive Output Voltage – SPI Version
Positive Output Voltage (Switch Out)
Output Current (IOUT)
Reverse Output Voltage
Reverse Output Current
Operating Ambient Temperature Range, TA
Storage Temperature Range, TS
Magnetic Flux Density
Value
+ 20 V
− 10 V
+ 10 V
+ 14 V (200 s max − TA = + 25°C)
VDD + 0.3V
+ 10 V
+ 14 V (200 s max − TA = + 25°C)
± 30 mA
− 0.3 V
− 50 mA
− 40°C … + 150°C
− 40°C … + 150°C
± 700 mT
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
6. Detailed Description
As described on the block diagram (Figure 1, Figure 2 and Figure 3), the magnetic flux density parallel to
the IC surface (i.e. B//) is sensed through the Tria⊗is® sensor front-end. This front-end consists into two
orthogonal pairs (for each of the two directions parallel with the IC surface i.e. X and Y) of conventional
planar Hall plates (blue area on Figure 5) and an Integrated Magneto-Concentrator (IMC® yellow disk on
Figure 5).
3901090316
Rev10
Hall Plates
Figure 5 - Tria⊗is® sensor front-end (4 Hall plates + IMC® disk)
Page 8 of 45
Jul/13