English
Language : 

MLX90316KDC-BDG Datasheet, PDF (26/45 Pages) Melexis Microelectronic Systems – Rotary Position Sensor IC
MLX90316
Rotary Position Sensor IC
IIR Filter - Gaussian White Noise Response
40200
40150
40100
40050
40000
39950
39900
39850
39800
0
x(n)
y(n)
50
100
150
Time
Figure 13 - Noise Response for the IIR Filter
14.6. Programmable Diagnostic Settings
Parameter
RESONFAULT
EEHAMHOLE
Value
Unit
0
1
0
3131h
14.6.1. RESONFAULT Parameter
This RESONFAULT parameter enables the soft reset when a fault is detected by the CPU when the
parameter is set to 1. By default, the parameter is set to “0” but it is recommended to set it to “1” to
activate the self diagnostic modes (See section 15).
Note that in the User Interface (MLX90316UI), the RESONFAULT is split in two bits:
• DRESONFAULT: disable the reset in case of a fault.
• DOUTINFAULT: disable output in diagnostic low in case of fault.
14.6.2. EEHAMHOLE Parameter
The EEHAMHOLE parameter disables the CRC check and the memory recovery (Hamming code) when it
is equal to 3131h. Melexis strongly recommends to set the parameter to 0 (enable memory recovery).
This is done automatically when using the MEMLOCK function.
14.7. Lock
3901090316
Rev10
Parameter
MLXLOCK
LOCK
Value
0
1
0
1
Page 26 of 45
Unit
Jul/13