English
Language : 

MLX90316KDC-BDG Datasheet, PDF (17/45 Pages) Melexis Microelectronic Systems – Rotary Position Sensor IC
MLX90316
Rotary Position Sensor IC
… End-User Programmable Items
FSWAP
FORCECRA75
Radius Adjustment to 75%
AUTO_RG
Automatic Rough Gain Selection
RoughGain
RGThresL
RGThresH
EEHAMHOLE
RESONFAULT
MLXLOCK
MLX90316BCS
LOCK
MLX90316BCS
Parameter for MLX90316xDC-BCS only
OUT2EN
OUT2 SLOPE RATIO
Was CUSTUMERID2
OUT2 OFFSET
CLAMP_LOW OUT2
CLAMP_HIGH OUT2
1
1
0
1
1
0
0/1
0
0
1
0
1
1
1
1
9
0
3
0
8
6
N/A
3
N/A
8
0
0
0
0
4
15
15
15
15
4
3131h
0
0
0
16
0
1
1
1
2
0
1
1
1
1
0
1
1
1
1
0
N/A
0
N/A
1
1
N/A
1
N/A
1
N/A
N/A
-1
N/A
8
MLX
N/A 100% N/A
8
8%
N/A
10%
N/A 16
8%
N/A
90%
N/A 16
14. Description of End-User Programmable Items
14.1. Output Mode
The MLX90316 output type is defined by the Output Mode parameter.
Parameter
Analog Output Mode
PWM Output Mode
Serial
Value
2, 4
5
7
N/A
Description
Analog Rail-to-Rail
Low Side (NMOS)
Push-Pull
Low Side (NMOS)
14.1.1. Analog Output Mode
The Analog Output Mode is a rail-to-rail and ratiometric output with a push-pull output stage configuration
allows the use of a pull-up or pull-down resistor.
14.1.2. PWM Output Mode
If one of the PWM Output modes is selected, the output signal is a digital signal with Pulse Width
Modulation (PWM).
In mode 5, the output stage is an open drain NMOS transistor (low side), to be used with a pull-up resistor
to VDD.
In mode 7, the output stage is a push-pull stage for which Melexis recommends the use of a pull-up
resistor to VDD.
The PWM polarity is selected by the PWMPOL1 parameter:
• PWMPOL1 = 0 for a low level at 100%
• PWMPOL1 = 1 for a high level at 100%
3901090316
Rev10
Page 17 of 45
Jul/13