English
Language : 

MLX90316KDC-BDG Datasheet, PDF (31/45 Pages) Melexis Microelectronic Systems – Rotary Position Sensor IC
MLX90316
Rotary Position Sensor IC
16.8. Timing
To synchronize communication, the Master deactivates /SS high for at least t5 (1.5 ms). In this case, the
Slave will be ready to receive a new frame. The Master can re-synchronize at any time, even in the middle
of a byte transfer.
Note: Any time shorter than t5 leads to an undefined frame state, because the Slave may or may not
have seen /SS inactive.
t6 t1
SCLK
t1 t7 t1
t1
t1 t2
MOSI/
MISO
/SS
2 Startbytes
Byte 0
Byte 1
Byte 2
t4 t9 t5
Byte 7
Timings
t1
t2
t4
t5
t5
t6
t7
t9
TStartUp
Min(25)
2.3 µs / 6.9 µs
12.5 µs / 37.5 µs
2.3 µs / 6.9 µs
300 µs / 1500 µs
0µs
2.3 µs / 6.9 µs
15 µs / 45 µs
-
-
Max
-
-
-
-
-
-
-
<1 µs
< 10 ms / 16 ms
Remarks
No capacitive load on MISO.
t1 is the minimum clock period for any
bits within a byte.
t2 the minimum time between any other
byte
Time between last clock and
/SS=high=chip de-selection
Minimum /SS = Hi time where it’s
guaranteed that a frame re-
synchronizations will be started.
Maximum /SS = Hi time where it’s
guaranteed that NO frame re-
synchronizations will be started.
The time t6 defines the minimum time
between /SS = Lo and the first clock edge
t7 is the minimum time between the
StartByte and the Byte0
Maximum time between /SS = Hi and
MISO Bus High-Impedance
Minimum time between reset-inactive
and any master signal change
25 Timings shown for oscillator base frequency of 20MHz (Fast Mode) / 7 MHz (Slow Mode)
3901090316
Rev10
Page 31 of 45
Jul/13