MAX16067 Datasheet, PDF (24/47 Pages) Maxim Integrated Products – 6-Channel, Flash-Configurable System Manager with Nonvolatile Fault Registers
6-Channel, Flash-Configurable System Manager
with Nonvolatile Fault Registers
Table 20. EN_OUT1–EN_OUT6 Configuration
REGISTER
ADDRESS
FLASH
ADDRESS
BIT RANGE
DESCRIPTION
[1:0]
EN_OUT1 Configuration
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull
EN_OUT2 Configuration
00 = Active-low, open drain
[3:2]
01 = Active-high, open drain
10 = Active-low, push-pull
30h
230h
11 = Active-high, push-pull
EN_OUT3 Configuration
00 = Active-low, open drain
[5:4]
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull
[7:6]
EN_OUT4 Configuration
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull
[1:0]
EN_OUT5 Configuration
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull
31h
231h
EN_OUT6 Configuration
00 = Active-low, open drain
[3:2]
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull
[7:4]
Not used
EN_OUT1 Charge-Pump Output Configuration
[0]
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
EN_OUT2 Charge-Pump Output Configuration
[1]
0 = Charge-pump output disabled
33h
233h
1 = Charge-pump output enabled (active-high)
[2]
[7:3]
EN_OUT3 Charge-Pump Output Configuration
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
Not used