English
Language : 

MAX1219 Datasheet, PDF (17/21 Pages) Maxim Integrated Products – 1.8V, Dual, 12-Bit, 210Msps ADC for Broadband Applications
1.8V, Dual, 12-Bit, 210Msps ADC for
Broadband Applications
VCLK
0.1µF
SINGLE-ENDED
INPUT TERMINAL 0.1µF
1
8
18 19
16
0.1µF
50Ω 510Ω
MAX9388
9
50Ω
50Ω
50Ω
510Ω
15
12 14 10
0.1µF
INAP/INBP
0.1µF
INAN/INBN
AVCC OVCC
CLKN CLKP
12
MAX1219
12
DA0P/N–DA11P/N, ORAP/N
DB0P/N–DB11P/N, ORBP/N
AGND
OGND
Figure 7. Differential, AC-Coupled, PECL-Compatible Clock Input Configuration
AVCC
OVCC
SINGLE-ENDED
INPUT TERMINAL 0.1µF
ADT1-1WT
ADT1-1WT
0.1µF
10Ω
INAP/INBP
24.9Ω
12
MAX1219
24.9Ω
10Ω
12
INAN/INBN
0.1µF
AGND
OGND
Figure 8. Analog Input Configuration with Back-to-Back Transformers and Secondary-Side Termination
DA0P/N–DA11P/N,
ORAP/N
DB0P/N–DB11P/N,
ORBP/N
Route the digital output traces for a high-speed, high-
resolution data converter with care. Keep trace lengths
at a minimum and place minimal capacitive loading,
less than 5pF, on any digital trace to prevent coupling
to sensitive analog sections of the ADC. Run the LVDS
output traces as differential lines with 100Ω characteris-
tic impedance from the ADC to the LVDS load device.
Static Parameter Definitions
Integral Nonlinearity (INL)
Integral nonlinearity is the deviation of the values on an
actual transfer function from a straight line. This straight
line can be either a best-straight-line fit or a line drawn
between the end points of the transfer function, once
offset and gain errors have been nullified. However,
the static linearity parameters for the MAX1219 are
measured using the histogram method with a 65MHz
input frequency.
______________________________________________________________________________________ 17