Pin Description (continued)
PIN
NAME
FUNCTION
46
CGC2
Channel 2 High-Side Clamp Gate Input. Connect a 1nF to 10nF capacitor between CDC2 and
CGC2 as close as possible to the device.
47
CDC2
Channel 2 High-Side Clamp Driver Output. Connect a 1nF to 10nF capacitor between CDC2 and
CGC2 as close as possible to the device.
48
VEE2
Channel 2 Negative Supply Input. |VEE2| P |VCC2|. Gate-drive supply voltage for the OCP2 clamp.
Bypass VEE2 to GND with a 0.1FF capacitor as close as possible to the device.
Logic Supply-Voltage Input. Bypass VDD to GND with a 0.1FF capacitor as close as possible to
49
VDD
the device. Depending on the pulser lead, additional bypassing may be required (see the Power
Supplies and Bypassing section).
50
VSS
Substrate Voltage. Connect VSS to a voltage equal to or more negative than the more negative of
VNN1 or VNN2. Bypass VSS to GND with a 0.1FF capacitor as close as possible to the device.
51
VEE1
Channel 1 Negative Supply Input. |VEE1| P |VCC1|. Gate-drive supply voltage for the OCP1 clamp.
Bypass VEE1 to GND with a 0.1FF capacitor as close as possible to the device.
52
CDC1
Channel 1 High-Side Clamp Driver Output. Connect a 1nF to 10nF capacitor between CDC1 and
CGC1 as close as possible to the device.
53
CGC1
Channel 1 High-Side Clamp Gate Input. Connect a 1nF to 10nF capacitor between CDC1 and
CGC1 as close as possible to the device.
56
CDP1
Channel 1 High-Side Driver Output. Connect a 1nF to 10nF capacitor between CDP1 and CGP1 as
close as possible to the device.
—
EP
Exposed Pad. EP must be connected to VSS. Do not use EP as the only VSS connection for the
device.