English
Language : 

822-1002-C01 Datasheet, PDF (36/40 Pages) Magnetrol International, Inc. – Kotron® Sentinel Models 822, 832 and 842
3.6 Parts
3.6.1 Replacement
No.
Description
Part Number
Non-hazardous
Z30-2409-001
Integral Hazardous
Amplifier
1
PC board
I.S. circuitry
Non-hazardous
Remote Hazardous
Z30-2409-001
Z30-2410-001
Z30-2410-002
Z30-2410-002
I.S. circuitry
Z30-2410-001
Note: Refer to model number digit 7 for proper amplifier PC board
Power supply/relay board:
Model 822
Model 832
Model 842
120 VAC Z30-2407-001 Z30-2407-002 Z30-2407-003
2 240 VAC Z30-2407-004 Z30-2407-005 Z30-2407-006
24 VDC Z30-2407-007 Z30-2407-008 Z30-2407-009
Preamplifier board:
A. Standard (remote)
Z30-2411-002
3
B. Intrinsically safe, remote (potted module) Z30-9005-001
C. Intrinsically safe, integral (potted module) Z30-9003-001
4 Intrinsically safe barrier (potted module)
Z30-9002-001
5 Housing
cover
NEMA 4X Carbon steel
NEMA 4X/7/9 Cast iron
NEMA 4X/7/9 Aluminum
089-6523-001
089-6554-002
089-6554-003
6 O-Ring
NEMA 4X
NEMA 4X/7/9
012-1318-001
012-2501-249
NEMA 4X Aluminum
single conduit
004-9165-002
7
Housing
base
NEMA 4X/7/9 Cast iron,
single conduit
004-9138-003
NEMA 4X/7/9 Aluminum
dual conduit
004-9173-003
Remote
8 probe
housing
Aluminum single conduit
316 SS, single conduit
9 Remote electronics
mounting bracket
1⁄ 2" NPT
3⁄ 4" NPT
089-6585-001
089-6585-002
036-3805-001
036-3805-003
Connecting cable up to 2500 ft. (760 m)
Intrinsically safe 800 ft. (240 m)
10 (shielded, twisted pair, 22-gauge stranded
conductors)
009-7146-001
2
5
4
9
3A
3B
8
1
3C
6
7
10
33