3.2 Specifications
3.2.1 Electrical
Supply voltage
Power consumption
Humidity
Electrostatic discharge protection
Response time
Ambient temperature
Temperature coefficient of set point
Maximum remote mount distance
Standard
Intrinsically safe
Data
Entry
Indication
Relays 2 to 4 DPDT
AC
DC
Set point range
Differential range
Time delay
120 VAC, 50/60 Hz (+10/-15%)
240 VAC, 50/60 Hz (+10/-15%)
24 VDC (±10%)
15 VA nominal
99% non-condensing (electronics)
Per IEC specification 801-2
70 ms to approximately 2 seconds, depending upon probe
capacitance and averaging value
-40° F to +160° F (-40° to +70° C)
±0.01%/degree F (±0.018%/degree C)
2500 feet (760 m)
800 feet (240 m)
3-button keypad
4-digit LED, 1 overflow LED for +10,000
10 amp @ 120/240 VAC resistive
10 amp @ 30 VDC resistive, 0.5 amp @ 125 VDC resistive
0–50,000 pF
0.50 pF minimum / 50,000 pF maximum
0–90 seconds level rising, falling, both
50-621 Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches
26