2.6.5.1 Measurement Type: Level Only (Loop Control = Level)
Display
Action
Comment
32
DispFact
(select)
Select Yes to display factory
parameter menus
33
History
Press Enter to view history Diagnostic Display
(current status) of exceptions
34
Run Time
35
History Reset Press Enter and select yes Similar to SZ Alarm Reset
to clear history
36
HF cable
(select)
Superuser Parameter
Select from 3-foot or 12-foot remote
37
FidTicks
xxxx
Diagnostic Display
Time of flight from start of ramp to fiducial
38
FidSprd
39
Fid Type
(select)
Superuser Parameter
40
Fid Gain
xxx
Superuser Parameter
41
Window
xxx
Factory Parameter
42
Conv Fct
xxxx
Factory Parameter
43
Scl Ofst
xxx
Factory Parameter
44
Neg Ampl
xxx
Superuser Password
45
Pos Ampl
xxx
Superuser Password
46
Signal
xxx
Diagnostic Display
47
Compsate
(select)
Superuser Password
48
DrateFct
xxxx
Diagnostic Display
49
Targ Ampl
xxxx
Diagnostic Display
50
Targ Tks
xxxx
Diagnostic Display
51
Targ Cal
xxxx
Diagnostic Display
52
OperMode
(select)
Superuser Password
53
7xKCorr
xxx
Superuser Password
54
ElecTemp
xxx C
Diagnostic Display
55
Max Temp
xxx C
Superuser Password
56
Min Temp
xxx C
Superuser Password
57
SZ Hyst
xx.x lu
Superuser Password
Select from positive or negative
(Selection only allowed for some probes)
Amount of gain applied to the fiducial signal
Calibration parameter
Calibration parameter
Diagnostic parameter
Diagnostic parameter
Indication of level signal amplitude
Select from None, Manual, Auto
Compsate = Auto. Velocity derating factor for Model 7xS Steam
probe
Compsate = Auto. Indication of steam reference target amplitude
Compsate = Auto. Measured time of flight from fiducial to steam
reference target
Compsate = Auto. Calibrated time of flight from fiducial to target
in room temperature air
Compsate = Auto. Select from Run, Cal, Off
Distance in mm from fiducial to user reference point
(7xK probe characteristic)
Present temperature in electronics compartment
(degrees Celsius)
Maximum electronics temperature recorded
Minimum electronics temperature recorded
57-600 Eclipse Guided Wave Radar Transmitter