2.6.5 Model 705 Menu: Step-By-Step Procedure
The following tables provide a complete explanation of
the software menus displayed by the Eclipse transmitter.
Use these tables as a step-by-step guide to configure the
transmitter based on a desired measurement type of:
• Level Only, Section 2.6.5.1
• Level and Volume, Section 2.6.5.2
• Interface Level, Section 2.6.5.3
• Interface Level and Volume, Section 2.6.5.4
The tables are separated to display the parameters based
on the measurement type. The second column presents
the menus shown on the transmitter display. The displays
are in the order they would appear if the arrow keys were
used to scroll through the menu. The numbers in the first
column are not shown on the display. They are only pro-
vided as a reference.
The third column provides the actions to take when con-
figuring the transmitter. Additional information or an
explanation of an action is given in the fourth column.
(Shaded sections are factory menu items).
2.6.5.1 Measurement Type: Level Only (Loop Control = Level)
Display
*Status*
1
*Level *
*% Out *
* Loop *
2
Level
xxx.x
3
% Output
xx.x%
4
Loop
xx.xx mA
5
PrbModel
(select)
6
PrbMount
(select)
7
MeasType
(select)
8
LvlUnits
(select)
9
Probe Ln
xxx.x
10
Lvl Ofst
xxx.x
11
Dielctrc
(select)
Action
Transmitter Display
Transmitter Display
Comment
LoopCtrl = Level.
Transmitter default display showing Status, Level, % Output, and
Loop values cycles every 5 seconds
Transmitter displays Level Value in selected units
Transmitter Display
Transmitter Display
Transmitter displays % Output measurement derived from 20 mA
span
Transmitter displays Loop value (mA)
Select the type of probe
used
(Example: 7xR-x)
Select from 7xA-x, 7xB-x, 7xD-x, 7xE-x, 7xF-x, 7xF-E, 7xF-F,
7xF-4, 7xG-x, 7xF-P, 7xG, 7xJ-x, 7xK-x, 7xL, 7xM, 7xN, 7xP-x,
7xR-x, 7xS-x, 7xT-x, 7x1-x, 7x2-x, 7x5-x, 7x7-x as shown on
the probe nameplate
Select the type of probe
mounting
Select type of measurement
Select from NPT, BSP, or Flange
Select Lvl Only
Select level units
Select from cm, inches, feet or meters
Enter the exact length of
probe
Enter the desired reading
when probe is dry
Select range bounding the
dielectric constant of the
media
Probe length is printed on the nameplate and order information
and is the last three digits of the probe model number
Level Offset is the distance from the probe tip to the desired 0
level point (-90 to 300"). Refer to Section 2.6.6
Select from 1.4–1.7; 1.7–3; 3–10; 10–100
57-600 Eclipse Guided Wave Radar Transmitter
21