MAZS360GML Datasheet, PDF (8/22 Pages) Tyco Electronics – Telecommunications & Networking Devices
Table T3 Electrical Characteristics for Telecommunications and Networking Devices
Cont’d
Part
IH
Number
(A)
Surface-mount† — 600VAC
TS600/TSM600
TS600-170F
0.170
TS600-200F-RA-B-0.5 0.200
TS600-400F
0.400
TSM600-250F
0.250
TSM600-250F-RA 0.250
TSM600-400F
0.400
VMAX
IMAX*†
IT
Operating Interrupt Interrupt PDTyp
(A)
(VDC)
(VRMS)
(A)
(W)
0.400
60
600
3.0
2.5
0.400
60
600
3.0
2.5
1.000
60
600
3.0
2.0
0.860
250
600
3.0
2.0
0.860
250
600
3.0
2.0
1.000
250
600
3.0
2.0
Typical Time-to-trip
(A)
(s)
RMIN
(Ω)
RMAX
(Ω)
R1MAX
(Ω)
1.0
10.0
4.0
9.0
18.0
1.0
12.0
4.0
7.5
13.5
3.0
5.0
0.5
1.5
2.0
3.0
0.8
1.0
3.5
7.0
3.0
1.0
1.0
3.0
5.0
3.0
5.0
0.5
1.5
2.0
Notes:
IH
: Hold current: maximum current device will pass without interruption in 20°C still air.
IT
: Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air.
VMAX Operating : Maximum continuous voltage device can withstand without damage at rated current. This voltage is used for component recognition under UL1434.
VMAX Interrupt : Maximum voltage that can be safely placed across a device in its tripped state. Devices have been designed to trip safely under higher level power cross conditions
to assist equipment in meeting the appropriate ITU, UL60950, or GR1089 industry requirements.
IMAX Interrupt : Maximum fault current device can withstand without damage at rated operating voltage. This current is used for component recognition under UL1434.
Devices have been designed to trip safely under higher level power cross conditions to assist equipment in meeting the appropriate ITU, UL60950, or GR1089
industry requirements.
PD
RMIN
RMAX
R1MAX
: Power dissipated from device when in the tripped state in 20°C still air.
: Minimum resistance of device as supplied at 20°C unless otherwise specified.
: Maximum resistance of device as supplied at 20°C unless otherwise specified.
: Maximum resistance measured one hour post-trip or post-reflow at 20°C.
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.
† 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
Warning :
• Users should independently evaluate the suitability of and test each product selected for their own application.
• Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame.
• These devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should
not be used when repeated fault conditions or prolonged trip events are anticipated.
• Contamination of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices.
• Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, and
mechanical procedures for electronic components.
• PPTC devices are not recommended for installation in applications where the device is constrained such that its PTC properties are inhibited,
for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion.
• Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of the device.
Figure T2-T13 Dimension Figures for Telecommunications and Networking Devices
12
Figure T2
Figure T3
Figure T4
A
C
B
A
C
B
A
C
B
D
E
CL to CL
D
E
CL to CL
220