English
Language : 

MAZS360GML Datasheet, PDF (13/22 Pages) Tyco Electronics – Telecommunications & Networking Devices
Physical Characteristics and Environmental Specifications for
Table T5
Telecommunications and Networking Devices
Cont’d
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C to 85°C)
TRF250*
Physical Characteristics
Lead material
Tin-plated copper, 22AWG
Insulating material
Cured epoxy polymer
Flammability
per IEC 695-2-2 Needle Flame Test for 20s
Soldering characteristics ANSI/J-STD-002, Category 3
Solder heat withstand
IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: can withstand 10 seconds at 260°C±5°C
Note: Devices are not designed to be placed through a reflow process.
Environmental Specifications
Test
Passive aging
Conditions
60°C, 1000 hours
Humidity aging
Thermal shock
85°C, 1000 hours
85°C, 85% RH, 1000 hours
125°C, -55°C (10 times)
Solvent resistance
MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TS250/TSV250/TSL250*
Physical Characteristics
Terminal material
Soldering characteristics
Tin-plated brass, Nickel under-plating
EIC 60008-2-58
Environmental Specifications
Test
Conditions
Passive aging
Humidity aging
60°C, 1000 hours
85°C, 1000 hours
85°C, 85% RH, 500 hours
Thermal shock
Solvent resistance
125°C, -55°C (10 times)
MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TRF600†
Physical Characteristics
Lead material
Insulating material
Tin-plated copper, 22AWG
Cured epoxy polymer‡
Flammability
per IEC 695-2-2 Needle flame test for 20s
Soldering characteristics ANSI/J-STD-002, Category 3
Solder heat withstand
IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: can withstand 10 seconds at 260°C±5°C
Note: Devices are not designed to be placed through a reflow process.
Environmental Specifications
Test
Passive aging
Conditions
60°C, 1000 hours
Humidity aging
Thermal shock
85°C, 1000 hours
85°C, 85% RH, 1000 hours‡
125°C, -55°C (10 times)
Solvent resistance
MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.
† 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
‡ Excluding TRF600-150 and TRF600-400, which have a coating that is not rated for dielectric withstand and can withstand 500h at 85°C/85% RH or 1000h at 60°C/90% RH.
12
RoHS Compliant, ELV Compliant
225