Typical Time-to-trip Curves at 20°C for
Figure T14-T17
Telecommunications and Networking Devices
TS250/TSV250/TSL250
A = TSV250-130F
B = TS250-130F
C = TSL250-080F
Figure T16
100
A
B
C
10
Cont’d
1
A
B
0.10
C
TRF600/TS600/TSM600
A = TRF600-400/TS600-400/
TSM600-400F
B = TSM600-250F/
TS600-170F/200F
C = TRF600-160
D = TR600-150F-EX
E = TRF600-150
0.01
0.00
0.50
1.00
1.50
2.00
2.50
Fault Current (A)
Figure T17
1000
B
C
100 D
A
E
10
1
0.1
0.01
0
1
2
3
4
5
6
Fault Current (A)
3.00
A
B
C
D
E
7
12
224
Physical Characteristics and Environmental Specifications for
Table T5
Telecommunications and Networking Devices
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C to 85°C)
TCF250*
Physical Characteristics
Terminal material
Nickel-plated copper foil
Environmental Specifications
Test
Passive aging
Conditions
60°C, 1000 hours
85°C, 1000 hours
Humidity aging
Thermal shock
Solvent resistance
85°C, 85% RH, 1000 hours
125°C, -55°C (10 times)
MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements.
RoHS compliant, ELV compliant