POWER MANAGER ELECTRICAL CHARACTERISTICS
The l denotes specifications that apply over the full operating temperature range, otherwise specifications are at TA = 25°C (Note 2),
VBUS = 5V, VBAT = 3.8V, HPWR = SUSP = BUCK_ON = 0V, RPROG = 1.87k, STBY = high, unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS
MIN TYP MAX UNITS
IBVINQ
BVIN Input Current
Buck Shutdown
Buck Enabled, Standby Mode
Buck Enabled
VBUS = 0V, VBVIN = 3.8V, ISW = 0 (Note 8)
BUCK_ON = 0V
BUCK_ON = STBY = 3.8V
BUCK_ON = 3.8V, STBY = 0V
0.01
1
μA
1.5
3
μA
22
38
μA
IVINLDOQ
VINLDO Input Current
LDO Shutdown (Hard Reset)
LDO Enabled
VBUS = 0V, VINLDO = 3.8V, ILDO = 0 (Note 10)
0.01
1
μA
0.1
1
μA
Input Power Supply
VBUS
IBUS(LIM)
Input Supply Voltage
Total Input Current
HPWR = 0V (100mA)
HPWR = 5V (500mA)
4.35
5.5
V
l 80
90
100
mA
l 400
450
500
mA
VUVLO
VBUS Undervoltage Lockout
Rising Threshold
Falling Threshold
3.8
3.9
V
3.5
3.6
mV
VDUVLO
VBUS to BAT Differential Undervoltage
Lockout
Rising Threshold
Falling Threshold
200
300
mV
0
50
mV
RON_ILIM
Input Current Limit Power FET
On-Resistance (Between VBUS and VOUT)
Battery Charger
350
mΩ
VFLOAT
ICHG
VPROG
VPROG,TRKL
hPROG
ITRKL
VTRKL
ΔVRECHRG
tTERM
tBADBAT
hC/10
RON_CHG
TLIM
VBAT Regulated Output Voltage
Constant-Current Mode Charge Current
PROG Pin Servo Voltage
PROG Pin Servo Voltage in Trickle Charge
Ratio of IBAT to PROG Pin Current
Trickle Charge Current
Trickle Charge Threshold Voltage
Recharge Battery Threshold Voltage
Safety Timer Termination Period
Bad Battery Termination Time
End-of-Charge Indication Current Ratio
Battery Charger Power FET
On-Resistance (Between VOUT and BAT)
Junction Temperature in Constant
Temperature Mode
0 ≤ TA ≤ 85°C
RPROG = 1.87k, 0 ≤ TA ≤ 85°C
VBAT < VTRKL
VBAT < VTRKL
VBAT Rising
VBAT Falling
Threshold Voltage Relative to VFLOAT
Timer Starts when VBAT = VFLOAT – 50mV
VBAT < VTRKL
(Note 6)
IBAT = 200mA
4.179 4.2 4.221
V
4.165 4.2 4.235
V
380 400
420
mA
1
V
0.1
V
750
mA/mA
30
40
50
mA
2.9
3
V
2.6 2.75
V
–75 –100 –125
mV
3.2
4
5
Hour
0.4
0.5
0.63
Hour
0.085 0.1 0.115 mA/mA
220
mΩ
110
°C
NTC
VCOLD
VHOT
VDIS
Cold Temperature Fault Threshold
Voltage
Rising NTC Voltage
Hysteresis
Hot Temperature Fault Threshold Voltage Falling NTC Voltage
Hysteresis
NTC Disable Threshold Voltage
Falling NTC Voltage
Hysteresis
75
76
77
%VBUS
1.3
%VBUS
34
35
1.3
36
%VBUS
%VBUS
l 1.2
1.7
2.2 %VBUS
50
mV
INTC
NTC Leakage Current
VNTC = VBUS = 5V
–50
50
nA